1-877-Poolhub/877-766-5482 for Help

Customer Service Policy Details Privacy Policy Pool Tips Testimonials
         
        View Cart Site Map
 
Sort By Manufacturer
Your Navigation: Home> Controllers>  Intermatic Switches

     

Browse By Product Catalog

   
* Aboveground Cleaners
* Aboveground Filters
* Aboveground Heaters
* Aboveground Pool Liners
* Aboveground Pumps
* Aboveground Systems
* Alternative Sanitizers
* Automatic Pool Cleaners
* Chemical Products
* Chlorine Generators
* Pond Products
* Pool Controllers
* Pool Filters
* Pool Lighting
* Pool Heaters (Gas)
* Pool Heat Pumps
* Pool Pumps
* Pool Toys
* Replacment Filters
* Replacement Motors
* Solar Blankets and Reels
* Solar Heating
* Submersible Pumps
* Valves & Plumbing
* Wintercovers

Special Pool Needs

   
* Pool Parts Request
* Pool Consultations
* Content Library
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
 

Intermatic 24 Hr. Mechanical Switches

 
T100 Series: Highest HP ratings in the industry for loads up to 40 amps, providing direct 24 hrs. control. Has 1 to 12 “ON/OFF” operations each day with minimum of on/off times of 1 hr. All models equipped with one “ON” and one “OFF” tripper. Additional trippers ordered separately. See below.         

*All models shown have plastic rust-proof case   

*NEMA 3R Case - 9-3/8" (23.8 cm) high x 5-1/2" (14.0 cm) wide x 3-5/8" (9.2 cm) tall. Agency Approval - CSA/C-US

*Knockouts - Combination 1/2" - 3/4" nominal knockouts, one on the back and each side of case, two on bottom.                                 

 
The two-circuit switches (P201 models) provide coordinated control for heater and filter pump operations and are designed to turn off a gas fired swimming pool heater approximately 20 minutes before the filter pump shuts down. Eliminates the problem of pounding and knocking due to overheated water, reduces scale and lime deposits and extends the service life of the heater. The heater control switch (fireman switch) is closed when the time switch contacts are open to allow remote operation of the heater. A flow or pressure-switch therefore must always be part of the heater control circuit. 
   
 

INTERMATIC 24 HR. MECHANICAL SWITCHES Buyers Guide

Model No. Switch Amps(per pole) Clock Motor Volts 60HZ HP Rating Wt. Price To Purchase
T101P3 Single Post 40 125 2 4 lbs. 69 Buy Now
T104P3 Double Post 40 208-277 5 4 lbs. 69 Buy Now
T101P201 Single post/2-circuit 40 125 2 4 lbs. 95 Buy Now
T104P201 Double post/2-circuit 40 208/277 5 4 lbs. 99 Buy Now
156T1978A On/Off Trippers   Set of 2 trippers   2 oz. 4.00 Buy Now